母線槽的定期檢修要做到什么地步

文章來源:http://www.yeeones.com/?? 作者:電纜橋架廠家發布時間:2022-12-02?瀏覽次數:

返回:常見問題
現在,電力消耗在增加。為了滿足電力需求,母線槽設備可以保證大電流的輸送和安全使用。那么你知道這種產品要定期檢修什么嗎?下面濟南電纜橋架廠家為您講解。
Now, power consumption is increasing. In order to meet the power demand, bus duct equipment can ensure the transmission of large current and safe use. Do you know what this product needs to be overhauled regularly? Next, Jinan cable tray manufacturer will explain to you.
檢修母線通道前,須先將配電柜斷電,并掛上“有人操作,不準合閘”的標牌,并派專人監護。檢修工作開始前,應檢查并放電,接地棒使用后,可進行相間回路和可靠接地。
Before the maintenance of the bus passage, the power distribution cabinet must be cut off first, and the sign "No switching on, no switching on" must be hung, and a special person must be assigned for monitoring. Before maintenance, check and discharge. After using the grounding rod, the interphase circuit and reliable grounding can be carried out.
定期檢查母線槽各進線端子電壓,確認母線槽已完全切斷電源。經常用軟刷、吸塵器或棉花擦拭母線槽上的灰塵。母線槽的總負載電流不得超過主母線電流或設計電流。
Regularly check the voltage of each incoming terminal of the bus duct, and confirm that the bus duct has completely cut off the power supply. Frequently wipe the dust on the bus duct with a soft brush, vacuum cleaner or cotton. The total load current of the bus duct shall not exceed the main bus current or design current.
檢查作業現場溫度。設備安裝使用后3個月內檢查連接螺栓是否松動,1年后多面檢查,其余每3年完全檢查一次。
Check the temperature of the operation site. Check whether the connecting bolts are loose within 3 months after the equipment is installed and used. After 1 year, check the connection bolts on multiple sides, and check the rest every 3 years.
特別注意接頭的夾緊扭矩和表面清潔。如果結構松動或被污染,電阻會增加,過熱。即使是不平整的連接面也可能出現電弧現象。
Pay special attention to the clamping torque and surface cleanliness of the joint. If the structure is loose or polluted, the resistance will increase and overheat. Even uneven joint surfaces may be arced.
濟南電纜橋架
如果母線槽長期運行,應至少每年定期檢查以確保安全,然后檢查總負載電流不超過設計電流和主母線槽的額定電流。
If the bus duct operates for a long time, it shall be checked regularly at least every year to ensure safety, and then check that the total load current does not exceed the design current and the rated current of the main bus duct.
在維護母線槽之前,須檢查母線槽系統是否已斷電!切斷所有母線槽的電源!
Before maintaining the bus duct, check whether the bus duct system is powered off! Cut off the power supply of all bus ducts!
此外,該儀器用于測量導線中是否有電壓,在確認母線槽系統未充電后,可進行日常維護,以防止高壓對操作人員造成傷害。
In addition, the instrument is used to measure whether there is voltage in the conductor. After confirming that the bus duct system is not charged, routine maintenance can be carried out to prevent high voltage from causing injury to operators.
雖然母線槽所承載的大電流可以滿足人們的用電需求,但在使用過程中還存在許多問題需要注意。在使用過程中應定期進行維護和檢查,以確保母線槽電流傳輸的安全。有不明白的地方歡迎來我們這里http://www.yeeones.com咨詢!
Although the large current carried by the bus duct can meet the power demand of people, there are still many problems that need attention in the use process. During use, regular maintenance and inspection shall be carried out to ensure the safety of bus duct current transmission. Welcome to us if you don't understand http://www.yeeones.com consulting service